Many pneumatic technicians do not realize that the pneumatic equipment in the workshop needs to be processed and maintained every day. If only a single device is cleaned, there may be no way to check the residue under the solenoid valve seal. Please take a moment to clear all the debris on the seal. If any of the seals or pneumatic clamps are broken, then you need to replace them during the cleaning process.
How to clean?
First, you need to prepare a clean, lint-free cloth material, remember not to choose a cloth that is easy to shed. Keeping this surface dry will help ensure that corrosion does not occur, so that your solenoid valve will keep functioning for years to come. All machines need to ensure that they are turned off and cooled so that they will not receive any voltage and avoid some potential hazards. Carefully observe whether the solenoid valve is slightly corroded. Once found, remove the corroded surface immediately. It is worth noting that general corrosion is easy to spread to other parts, so replacement is actually the best measure.
Removal and installation of solenoid valve
Since the valve assembly of the solenoid valve is to be checked, it must be isolated from other air flows. Follow the steps one by one to remove the top nut, plate and coil. If you are a novice, please place these parts near the valve so that you can be sure to install it back in place. The nut is the most important part, so be sure to wipe it with a dry cloth that will not leave fluff. After disassembling these parts, remember to take out the armature tube and spring assembly, carefully observe whether they can move automatically in the tube, and whether there are any obstacles. Check all seals and O-rings for contamination that may occur during normal use. Once you take the time to clean up everything, there are other tips to make your work easier.
Replacement parts
Different types of pneumatic solenoid valves must have differences in some performance, especially for the effect of resisting dirt. A lot of research and data show that solenoid valves connected to stainless steel connectors can usually bring better performance and resist more dirt. Taking the time to replace your accessories can bring significant improvements.
Discover potential problems
All equipment will eventually fail due to improper storage or lack of maintenance. For solenoid valves, coil and valve failures are the most prone to occur. If an incorrect voltage is applied to the coil, the probability of failure will be very high. Therefore, choosing the originals and a series of operating specifications provided by the original equipment manufacturer will help you avoid such problems as much as possible. In addition, the gears in the solenoid valve also need to receive regular cleaning services. You only need to wipe the housing with a gentle cloth to ensure that they are free of debris that may enter the moving parts.
Vilop hopes to help you find the solenoid valve you need. We stock the best pneumatic parts and can provide alternatives to the discontinued series. If you notice that any other parts need to be replaced, please be sure to contact us online and tell us more about your company's requirements. We will make sure to help you find the pneumatic components you need to make all your equipment work again.